Commit Message Contributor Files Modified Lines Added Lines Removed Code Location Date
fix undefined GSM reset interval and heaterMode More... over 11 years ago
separate heater mode setting from start heater menu functions. Correct dead lock (cant turn heater on again) in case heater is not connected. More... over 11 years ago
fix beep frequency More... over 11 years ago
Some bug fixes for openegg: Correct timer clock (was running too fast). Make key press autorepeat faster. Fix GSM flash area corruption. More... over 11 years ago
Add K-line hardware info, so that people hopefuly stop asking again and again the same stuff. More... over 11 years ago
Use different linker section for settings to avoid conflict with GSM. More... over 11 years ago
Add sanity check to parser to avoid potential memory corruption More... over 11 years ago
Assume some defaults for CAF, PSENSOR and NOZZLE since most people wont care about those anyway. More... over 11 years ago
fix compile problems. More... over 11 years ago
some fix forgotten to check in and I already do not remember what it does fix. More... over 11 years ago
Fix CAF inconsistency. Enable CP during ignition, this prevents overheating during restart when the water in the heat exchanger is still quite hot. More... over 12 years ago
Sensor thresholds. More... over 12 years ago
Apply feedback from field tests. Add script to plot Data Top data logs. More... over 12 years ago
Make voltage measurement more accurate by considering polarity protection diode voltage drop. More... almost 13 years ago
Parametrize make for different hardware variants of heater device. Status: Hago + Toy CAF setup works, Delavan + DBW46 CAF does not. More... almost 13 years ago
Adjust partial load CAF. More... almost 13 years ago
Tune Full load. Still some black smoke during start. More... almost 13 years ago
Partial load running OK. Full load needs new tuning of parameters. More... almost 13 years ago
Fix (untestet) electrical switch on/off through second w-bus line. Adapt CAF settings, correct scale of Heating Power value, currently used for compressor pressure in centibar. More... almost 13 years ago
Working parameters for cheap CAF and Hago .2 nozzle. More... almost 13 years ago
Enable dosing pump cold thick oil problem preheating during glow sequence. Some small CAF changes. More... almost 13 years ago
Add cold thick oil dosing pump preheating work around. More... almost 13 years ago
Fix compilation (missing include) for Linux 3.4.7. More... almost 13 years ago
First working data set for part load / full load switching. Not optimal, but operational. More... about 13 years ago
Add toy blower scale factor to adapt the air flow mass. Tune CAF PID parameters again since previous values where flawed due to problems with the optical reflection RPM sensor (doubled pulses at low RPM). More... over 13 years ago
Working version, start rather suboptimal (smoke). More... over 13 years ago
Parametrize full load and partial load values. More... over 13 years ago
Fix overflow on msp430 of sequencer values. Deactivate GK and FPW modulation. More... over 13 years ago
Work in progress. More... over 13 years ago
Adapt CAF values to RPM domain (was RPS). More... over 13 years ago