Commit Message Contributor Files Modified Lines Added Lines Removed Code Location Date
Stop cooldown when flame detector goes below 10 More... about 14 years ago
Add units to actuators. More... about 14 years ago
parameter update (heater worked with vegoil and other shit). More... about 14 years ago
Heater parameters: First uninterrupted run, heated a bucket of about 10 Liters from 15 upto 80 degrees celcius. During rampup there is still a phase of black smoke, which will hopefully disappear by splitting the ramp up sequence into 2 sequences. More... over 14 years ago
heater parameter tuning. More... over 14 years ago
Untested changes on openegg: disable timer once it trigger one time or the heater shuts down by any other means. Avoid backlight toggling when lcd control is done repeatedly. More... over 14 years ago
Fix command refresh timeout. Update heater parameters, ignition works so far, full power still with white smoke and flame blow out. More... over 14 years ago
Do global task wakeup only if a new state was scheduled. This was also causing sequencer timing inaccuracies during diagnosis when W-Bus messages are being received all the time. More... over 14 years ago
record all error which lead to a different state than the current state, thus avoiding error flooding and also recording error during HT_OFF state. Timing changes from last check seem to be OK, some few test with the heater hardware show sequencer timing accuracy improvements as expected. More... over 14 years ago
Change heater ticks to something exactly divisible to the jiffy counters in order to avoid accumulating errors for time counting. Not yet tested, to be done later because of inminent danger of getting keys imprinted into the forehead. More... over 14 years ago
Change CAF RPS measurement back to period measuring method, since actual RPS counting in second intervals has to much delay for the control loop to work correctly. Add timeout for setting the RPS to zero when the CAF does not rotate anymore. More... over 14 years ago
Use simpler method to measure RPM, but not tested yet (equipment is currently buried deep in the basement). More... over 14 years ago
Add PID based RPM control for combustion air fan. PID parameters are a first shot, there is still room for improvement (overshoot and stability). More... over 14 years ago
First steps adding combustion fan tachometer functionality. More... over 14 years ago
*** empty log message *** More... over 14 years ago
Improve dosing pump timing accuracy More... over 14 years ago
Fix octave script for octave 3.2 More... over 14 years ago
Parameter tuning BA session More... over 14 years ago
small parameter changes More... over 14 years ago
Parameter changes from LA tuning session. Lower compressor minimum value (feasible now that the compressor is free of oil improving a lot the control stability). More... over 14 years ago
Add compiler/linker flags to save memory. More... over 14 years ago
Add EEPROM reading and writing command (not tested since TTV supplemental heaters do not support it. More... over 14 years ago
Reduce oszilations for low compressor set value in Nozzle compressor PID controller parameters. More... over 14 years ago
Add W-Bus code bit definitions. Add some telestart data discovered and kindly shared by pczepek; Thanks a lot. More... over 14 years ago
Sequencer parameter corrections. More... over 14 years ago
Fix inverted over heating fuse bug. More... over 14 years ago
Update readme. More... over 14 years ago
Drop Combustion fan EMK regulator stuff (not used in the hardware anyway). Add over heating fuse to sensor pool and appropriate supervisor thresholds. More... over 14 years ago
Typo fixes and small wbsim updates. More... over 14 years ago
MingW/win32 work in progress. More... almost 15 years ago